Start with a load list, then measure it: a plug-in meter for anything with an AC plug, a DC clamp meter for the 12V circuits.

TL;DR: Quick Summary

  • The method: Multiply each load’s watts by its hours per day, divide AC loads by 0.85 for inverter losses, add the inverter’s idle hours, and total the column.
  • Worked example: With a 12V fridge, a propane furnace, a laptop, TV time and a morning coffee, the couple in this guide needs about 1,750 Wh a day. Covering one day without charging takes a LiFePO4 bank of roughly 205 Ah, reserve included.
  • Measure the big ones: Log the fridge over a full 24 hours, read AC loads in watts rather than volts × amps, and check the total against a battery monitor with charging switched off.

Introduction

An RV energy audit turns “we use a lot of power, I think” into one number: your daily use in watt-hours. Get that number right and every other decision gets easier: how many amp-hours of battery, how many watts of solar, how big an inverter. Get it wrong and you either haul around hundreds of pounds of capacity you never use or sit in a dark camper at 2 a.m. wondering why the inverter shut off.

By the end of this guide you’ll have three things: your daily watt-hours, a clear picture of which loads use the most, and the numbers to size a battery bank and solar array. The walk-through takes an hour or two, plus a day of logging for the fridge. The worked example uses realistic numbers to show the method; swap in your own as you go.

What You’ll Need

A notebook and the labels on your appliances get you a first estimate. Two inexpensive meters turn it into a measurement, which matters most for anything with a thermostat, because a label can’t tell you how often the compressor or blower actually runs.

  • A worksheet: a spreadsheet, or the table below copied into a notebook.
  • A plug-in watt meter for AC appliances. It reads real watts and logs kilowatt-hours over time.
  • A DC clamp meter that measures DC amps, for 12V circuits. An AC-only clamp meter can’t read them.
  • An inline DC watt meter (optional) to log a 12V fridge’s watt-hours over a full day.
  • A battery monitor, if your RV has one, to check your total at the end. Our guide to shunt-based battery monitors (opens in a new tab) explains how they count every amp in and out.
  • Your inverter’s datasheet for its zero-load (idle) power.
  • A flashlight and your phone camera for nameplates hidden behind appliances and inside cabinets.

Your RV Energy Audit Worksheet

Copy this table into a spreadsheet or notebook and add a row for every device you find. The steps below explain how to fill in each column, and the worked example after them shows a completed sheet.

Scroll sideways to see every column.

Load AC/DC Watts Hours/Day Wh/Day Battery Wh Measured?
Fridge
Lights
Water pump
Furnace blower
Vent fans
Always-on loads (detectors, control boards)
Inverter on, nothing running
AC device (via inverter)
Total

Battery Wh is the column that counts. For DC loads it’s the same as Wh/Day. This guide uses 85 percent inverter efficiency for planning, so for AC loads, divide Wh/Day by 0.85. If you measured a load at the battery side, enter that number as it is. Mark each row measured or estimated, so you know which numbers to firm up first.

How to Do an RV Energy Audit, Step by Step

  1. Pick a typical day and decide what runs on the battery. Picture a normal day off-grid, the kind you want the system to handle, and mark only what you’ll actually use without shore power. How each appliance runs matters as much as what it is. An absorption fridge on propane needs only a small 12V draw for its controls, but switched to 12V it heats with an element that draws 170 W on several Dometic models. A compressor fridge always runs on electricity. A propane furnace still needs 12V for its blower: Dometic lists 4.2 to 11.1 amps for its AFMD furnaces, depending on size. An electric water heater element or a space heater on high is a kilowatt-class load, so off-grid those stay on propane or wait for shore power. A microwave or coffee maker doesn’t need a separate system; it can run from the same bank as long as the inverter and wiring can carry the load.
  2. List every load, room by room. Walk through bedroom, bath, galley, living area and the exterior bays, and open every cabinet. Note the small stuff too: USB chargers, the water pump, LP and CO detectors, slide motors, vent fans, the stereo, the TV antenna booster and the control boards on the fridge, furnace and water heater. Small loads that run 24 hours a day are the easiest to forget, and they add up. Group everything into a 12V DC list and a 120V AC list.
  3. Find each load’s real watts. On DC, watts = volts × amps works fine. On AC, volts × amps gives you VA, which can be higher than the watts the appliance really uses, so read the W display on a plug-in meter instead. Look for input power: Greystone’s P10034AP-L3-FR02 RV microwave delivers 1,000 W of cooking power but is rated to draw 1,500 W. A 65 W laptop charger’s rating is its maximum output, not what the laptop actually draws. A fuse rating is no guide at all: a 20A fuse tells you what the wire is protected for, not what the device draws.
    Plug-in watt meter seated in a wall outlet with an appliance connected and a display reading 145.6 W
    A plug-in meter reads real watts at the outlet. Leave it connected to log kilowatt-hours over time.
  4. Measure what the label can’t tell you. A plug-in meter covers appliances with a standard plug within its rating; the Kill A Watt P4400, for example, handles up to 15 amps (1,875 VA). It can’t measure the roof air conditioner, other hardwired loads or the RV’s whole shore-power feed. For 12V circuits, set the DC clamp meter to DC amps, zero it with the jaws closed and away from any wire, and clamp one insulated conductor with the device running. Never clamp the positive and negative together: their currents cancel and the meter reads close to zero. For the fridge, log the energy over a full, representative 24 hours, longer if the weather swings. If the meter shows 0.6 kWh after 24 hours, enter 600 Wh/day; every on-off cycle is already in that number. To find your always-on loads, switch everything off, inverter included, and read the remaining current on the battery monitor or with the clamp on the main DC cable. A reading of 0.4A is about 5 W, or roughly 120 Wh a day.
    DC clamp meter closed on a single red cable, black return wire outside the jaws, display reading 4.20 A
    Zero the meter in DC-amp mode, then clamp one insulated conductor. The return wire stays outside the jaws.
  5. Estimate hours per day. Lights run during dark waking hours, the water pump a few minutes at a time, detectors and control boards 24 hours. A laptop’s draw changes with its workload and battery charging, so measure a normal session rather than using the charger’s maximum rating. If you didn’t log the fridge, use the compressor’s total running time: one that runs about a third of the time counts as 8 hours at its running watts, not 24.
  6. Calculate watt-hours per day. Multiply watts by hours for every row: an 18 W vent fan running 6 hours uses 108 Wh a day. Enter the result under Wh/Day.
  7. Convert AC loads to battery watt-hours. An inverter turns part of every watt-hour into heat, so each AC watt-hour costs more at the battery. Divide AC watt-hours by 0.85: a laptop using 135 Wh at the outlet pulls about 159 Wh from the battery. Don’t trust the datasheet’s best efficiency for this; inverters do worse with small loads like a laptop. And don’t convert anything you measured at the battery side, since the losses are already in it.
  8. Add the inverter’s idle hours, once. A switched-on inverter draws power even with nothing plugged in; the zero-load figure is in its datasheet. Count only the hours it sits on without any AC load, because the losses while something runs are already in the 0.85. Do the same with always-on loads: if your measured background draw already includes the detectors and control boards, don’t list them again.
  9. Total the column. The sum of the Battery Wh column is your daily energy use. Watt-hours are the number to keep; convert to amp-hours only when you size a bank or compare with a battery monitor, at the battery’s nominal voltage: 12.8V for LiFePO4, 12V for lead-acid.

Worked Example: A Full Day, Load by Load

A couple boondocks in a travel trailer on a cool fall weekend. They run a 12V compressor fridge, LED lights, a roof vent fan, the water pump and the propane furnace. On the inverter: a laptop, a TV and a morning pot of coffee. The inverter is on for 14 hours a day, three with something plugged in and eleven doing nothing, and off overnight. For this worked example, assume the fridge meter logs 0.6 kWh over 24 hours.

Scroll sideways to see every column.

Load AC/DC Watts × Hours Battery Wh
12V compressor fridge DC Meter: 0.6 kWh in 24 h 600
LED lights DC 15 W × 4 h 60
Roof vent fan DC 18 W × 6 h 108
Water pump DC 60 W × 0.2 h 12
Furnace blower DC 80 W × 3 h 240
Always-on loads (detectors, control boards, stereo memory) DC 5 W × 24 h 120
Inverter on, nothing running DC 10 W × 11 h 110
Laptop AC 45 W × 3 h ÷ 0.85 159
TV AC 70 W × 3 h ÷ 0.85 247
Coffee maker AC 800 W × 0.1 h ÷ 0.85 94
Total 1,750 Wh/day

The total is 1,750 Wh a day, or about 137 Ah from a 12.8V lithium bank and 146 Ah from a 12V lead-acid bank. Sort the column and the story is clear: the fridge and the furnace blower use nearly half the day’s energy between them. The coffee maker everyone worries about uses 94 Wh, less than the inverter burns doing nothing. Turning the inverter off whenever nothing needs AC is the cheapest saving on the sheet.

Daily battery energy chart: fridge 600 Wh, other DC loads 300, TV 247, furnace blower 240, laptop 159, inverter idle 110 and coffee maker 94
In the worked example, the fridge and furnace blower account for 840 Wh, or 48% of the day. The inverter uses more energy idling than the coffee maker uses brewing.

Check Your Total Against a Battery Monitor

A worksheet is an estimate until you’ve checked it. A shunt-based battery monitor makes that easy, as long as you know what it measures: the net current in and out of the battery. If solar is feeding your loads at the same time, the monitor only sees the part the battery supplies, not your full use.

With 200 W of DC loads and 150 W of solar, the battery supplies only 50 W; with charging off, it supplies the full 200 W
A battery monitor only sees the battery’s share. In this example, solar hides 150 W of a 200 W load; switching charging off makes the full draw visible.

So run the check with charging off. Unplug shore power, switch solar charging off with your system’s normal controls, such as the PV breaker or the charge controller’s app, and live on the battery for 24 hours, as long as the bank has the capacity. Note the consumed-Ah reading at the start and end, then compare the difference with your worksheet for the same period, before any reserve: about 137 Ah for the example’s lithium bank. If your bank can’t carry a full day, run the check from sunset to sunrise and compare it with the night-time rows of your sheet.

If the numbers land close together, your worksheet is good. If the monitor shows clearly more, look for forgotten always-on loads, run times that were longer than you estimated, or inverter hours you didn’t count.

Turn Your Total into Battery, Solar and Inverter Sizes

Battery Bank

Add a 20 percent reserve for run times that go long, a guest’s extra devices and the odd cold night, and the example’s design target becomes 2,100 Wh a day. Divide by the battery voltage and the share of capacity you plan to use. In this guide, that’s 80 percent for LiFePO4 and 50 percent for lead-acid; they’re planning levels, not hard limits for every battery.

Scroll sideways to see every column.

Battery and Planning Level One Day Without Charging Two Days Without Charging
LiFePO4, 12.8V, 80% usable About 205 Ah About 410 Ah
AGM or other lead-acid, 12V, 50% usable 350 Ah 700 Ah

The reserve and the extra days do different jobs. The reserve covers a day that runs long; each extra day without charging adds a full day’s energy. For the complete sizing method, including what your biggest load demands from the bank, see our guide to how many amp-hours you need for boondocking (opens in a new tab).

Solar Array

To replace the design target every day, divide it by your sun-hours and an efficiency factor:

Solar watts = design target (Wh) ÷ sun-hours ÷ 0.75

Sun-hours depend on where and when you camp, not on any datasheet. The free PVWatts calculator shows the solar radiation for your location month by month in kWh/m² per day, which is the same number. In this example, the 0.75 covers battery charging, panel temperature, controller and wiring losses; heavy shade needs more. With 4 sun-hours, the example needs 2,100 ÷ 4 ÷ 0.75 = 700 W of panels. With 5.5 sun-hours, about 510 W.

That array replaces one day’s planned use. Catching up after a cloudy stretch takes extra production, a generator or shore power. Our guide to sizing an RV solar array (opens in a new tab) goes deeper, and our solar panel tilt angle guide (opens in a new tab) shows how much tilting the panels adds in fall and winter.

Inverter

Your daily watt-hours set the energy you need. The inverter’s size depends on something else: what runs at the same time. The 800 W coffee maker uses just 80 Wh in a six-minute brew, less than the vent fan uses in a day, but while it brews the inverter has to deliver all 800 W. If the TV and laptop are on too, that’s 915 W, and that’s the number the inverter’s continuous rating has to clear, with headroom. Motors and compressors add a brief start-up surge on top. Our RV inverter sizing guide (opens in a new tab) explains continuous and surge watts.

Safety Considerations

  • Clamp only cables you can reach without opening the 120V panel or disconnecting anything. Measuring is not the same job as rewiring.
  • Take off rings and watches and keep metal tools clear of battery terminals. A 12V battery won’t shock you, but a short through a wrench or a ring can cause severe burns and start a fire.
  • If you upgrade the system, size each circuit’s cables for its maximum current and cable length, and choose fuses that protect those cables. A bigger bank doesn’t raise the current by itself; bigger loads do.
  • Adding lead-acid batteries? Make sure the compartment’s ventilation still suits the larger bank.

FAQs

  • Can I do an energy audit without meters? Yes. Nameplates and datasheets give you a solid first estimate. A plug-in meter for AC loads and a battery monitor make it accurate, so measure the fridge and anything else with a thermostat first: their labels say nothing about how often they run.
  • How long should I measure the fridge? At least a full 24 hours in conditions like your trips, and longer if the weather changes a lot. A daily total already includes every on-off cycle, so don’t multiply it by a duty cycle again.
  • Can the solar stay on while I check against my battery monitor? No. The monitor measures what flows in and out of the battery, so solar powering your loads directly hides part of your use. Switch charging off for the test. If the bank can’t last 24 hours, test overnight against the night rows of your worksheet.
  • How big a reserve should I add? This guide uses 20 percent, enough to absorb a day that runs longer than planned. Days without any charging are a separate decision: multiply by the number of days instead.
  • Should I work in watt-hours or amp-hours? Watt-hours. They don’t depend on voltage, so 12V and 120V loads add up directly. Switch to amp-hours only at the last step, for sizing the bank or checking against a battery monitor.

Conclusion

An energy audit takes an evening and a day of logging, and it pays off every time you change the rig. In the example, it turned a vague feeling into 1,750 Wh a day, showed that the fridge and furnace blower use nearly half of it, and produced clear targets: a LiFePO4 bank of about 205 Ah for one day without charging, or 410 Ah for two, and 510 to 700 W of solar, depending on where you camp. Keep the worksheet. When you swap the fridge, add a gadget or plan a longer trip, change one row and the totals update.